Engineering news

Multiple power take-off units

Advertiser

Multiple power take-off units
Multiple power take-off units

SPONSORED FEATURE

The multiple pump drive range of equipment allows a single or a multiple of pumps to be driven from a single prime mover.

Single pump drives allow a pump to be close coupled to a diesel engine that has a flywheel and flywheel housing in accordance with SAE standards (non standard can also be accommodated).

Supplied in a kit format consisting of a bell housing fully machined to suit the particular pump mounting and a flexible coupling to suit the engine flywheel and particular pump shaft.

Multiple pump drives allow two or more pumps to be driven from a single prime mover.

Available in a number of mounting formats, sizes and increasing and decreasing speed ratios.

All models may be close coupled directly to the prime mover (Model B) or may be fitted with an over-centre clutch (except AM 365 and AM 480) for close coupling (model BD) or for independent mounting (model BDS).

The multiple pump drive units are constructed from:-
- cast iron casings
- straight tooth gears case hardened and ground, shaved on AM216, AM320, AM220, AM330 series
- ball bearings
- case hardened shafts
- Viton seals on input shafts.

The fundamental elements on the selection of a pump drive are:-

1) The number and type of pumps. Depending on the overall dimensions of the pumps and associated pipework it is possible to
establish the maximum centre distances required.

2) Maximum torque requirement of each pump output. Verify that the maximum torque requirement is below the maximum value for each chosen pump or combination of pumps.

3) Maximum input torque. Verify that the maximum input torque is below the maximum indicated value for the particular model. In the case of a pump drive fitted with an over-centre clutch (models BD and BDS) it is important that the input torque is at least 20% below the maximum transmittable for that particular clutch.

4) Maximum input speed. Verify that the maximum input speed is below the maximum value indicated for that particular model. Check that the pump direction of rotation is opposite to that of the prime mover.

5) Service factor. A suitable safety factor should be applied to ensure the Integrity of the drive.

Full specification catalogue and contact details available at www.jbj.co.uk/splittergearboxes.html

Share:

Professional Engineering magazine

Professional Engineering app

  • Industry features and content
  • Engineering and Institution news
  • News and features exclusive to app users

Download our Professional Engineering app

Professional Engineering newsletter

A weekly round-up of the most popular and topical stories featured on our website, so you won't miss anything

Subscribe to Professional Engineering newsletter

Opt into your industry sector newsletter

Related articles